100G QSFP28Kejbils tar-ram Passivi ta' Waħħal Dirett
FOCC-DAC100G-CU * M
1,Karatteristiċi
Ø 4-cable tar-ram passiv full-duplex tal-kanal
Ø Rata tad-dejta sa 100Gbps (4x 25Gbps)
Ø Konnetturi QSFP28 konformi SFF-8665
Ø Interface ta' ġestjoni I2C konformi SFF-8636
Ø Konformi IEEE 802.3bj 100GBASE-CR4
Ø Tul tar-rabta tar-ram sa5m (limitazzjoni passiva)
Ø Sħun Pluggable
Ø Konsum ta 'enerġija baxxa
Ø Integrità tas-sinjal eċċellenti, telf ta 'inserzjoni baxx u crosstalk baxx
Ø Firxa tat-temperatura tal-każ operattiv: 0 grad sa +70 grad
Ø Vultaġġ tal-provvista waħda ta '3.3V
Ø RoKonformi HS

2,Applikazzjonijiet
Ø 100G Ethernet 100GBASE-CR4
Ø InfiniBand 4x EDR
Ø SAS, servers, ċentri, swiċċijiet u routers
Ø Ċentru tad-Data
3,Kundizzjonijiet Operattivi Rakkomandati
|
Parametru |
Simbolu |
Min |
Tipiku |
Massimu |
Unità |
|
Temperatura Ambjentali tal-Ħażna |
-40 |
+85 |
grad |
||
|
Temperatura tal-Każ Operattiv |
Tc |
0 |
+70 |
grad |
|
|
Vultaġġ tal-Provvista tal-Enerġija |
VCC3 |
3.14 |
3.3 |
3.47 |
V |
|
Rata tad-Data għal kull Korsija |
1 |
25.78 |
Gb/s |
4,Karatteristiċi ta' Veloċità Għolja
|
Parametru |
Simbo |
Min |
Tipiku |
Max |
Uni |
Nota |
|
Impedenza Differenzjali |
RIN,P- |
90 |
110 |
Ώ |
||
|
Telf ta' inserzjoni |
SDD21 |
22.48 |
Db |
F'12.8906 GHz |
||
|
Telf ta' Ritorn Differenzjali |
SDD11 |
Ara 1 |
Db |
Fi 0.05 sa 4.1 GHz |
||
|
SDD22 |
Ara 2 |
Db |
F'4.1 sa 19 GHz |
|||
|
Telf ta' ritorn tal-ħruġ tal-modalità komuni għal mod komuni |
SCC11 |
2 |
Db |
Fi 0.2 sa 19 GHz |
||
|
SCC22 |
||||||
|
Differenzjali għal telf ta 'ritorn tal-modalità komuni |
SCD11 |
Ara 3 |
Db |
Fi 0.01 sa 12.89 |
||
|
SCD22 |
Ara 4 |
F'12.89 sa 19 GHz |
||||
|
Differenzjali għal Telf ta' Konverżjoni tal-Modalità komuni |
SCD21 |
10 |
Db |
Fi 0.01 sa 12.89 |
||
|
Ara 5 |
Fil-12.89 sal-15.7 |
|||||
|
6.3 |
F'15.7 sa 19 GHz |
|||||
|
Marġni Operattiv tal-Kanal |
COM |
3 |
Db |
Noti:
1. Riflessjoni Koeffiċjent mogħtija minn ekwazzjoni SDD11(dB) < 16.5 - 2 × SQRT(f ), ma f fi Ghz
2. RFeleCtifuq Coefficient given by Equatifuq SDD11(dB) < 10.66 - 14 × log10(f/5.5), wit za ed f in GHz
3. Koeffiċjent ta' Riflessjoni mogħti mill-ekwazzjoni SCD11(dB) < 22 - (20/25.78)*f, b'f in Ghz
4. Riflessjoni Koeffiċjent mogħtija minn ekwazzjoni SCD11(dB) < 15 - (6/25.78)*f, ma f fi Ghz
5. Koeffiċjent ta' Riflessjoni mogħti mill-ekwazzjoni SCD21(dB) < 27 - (29/22)*f, b'f in Ghz
5,Baġit tat-telf tal-inserzjoni tal-kanal

6,Deskrizzjonijiet tal-Pin
|
Pin |
Loġika |
Simbolu |
Isem/Deskrizzjoni |
Noti |
|
1 |
GND |
Art |
1 |
|
|
2 |
CML-I |
Tx2n |
Input tad-Data maqluba tat-Trasmettitur |
|
|
3 |
CML-I |
Tx2p |
Input tad-Data Mhux Invertita tat-Trasmettitur |
|
|
4 |
GND |
Art |
1 |
|
|
5 |
CML-I |
Tx4n |
Input tad-Data maqluba tat-Trasmettitur |
|
|
6 |
CML-I |
Tx4p |
Input tad-Data Mhux Invertita tat-Trasmettitur |
|
|
7 |
GND |
Art |
1 |
|
|
8 |
LVTTL-I |
ModSelL |
Modulu Agħżel |
|
|
9 |
LVTTL-I |
IrrisettjaL |
Irrisettja l-Modulu |
|
|
10 |
Vcc Rx |
+3.3V Riċevitur tal-Provvista tal-Enerġija |
2 |
|
|
11 |
LVCMOSI/O |
SCL |
2-arloġġ tal-interface tas-serje tal-wajer |
|
|
12 |
LVCMOSI/O |
SDA |
2-dejta tal-interface tas-serje tal-wajer |
|
|
13 |
GND |
Art |
1 |
|
|
14 |
CML-O |
Rx3p |
Riċevitur Non-Invertited Data Output |
|
|
15 |
CML-O |
Rx3n |
Riċevitur Invertit Output tad-Data |
|
|
16 |
GND |
Art |
1 |
|
|
17 |
CML-O |
Rx1p |
Riċevitur Non-Invertited Data Output |
|
|
18 |
CML-O |
Rx1n |
Riċevitur Invertit Output tad-Data |
|
|
19 |
GND |
Art |
1 |
|
|
20 |
GND |
Art |
1 |
|
|
21 |
CML-O |
Rx2n |
Riċevitur Invertit Output tad-Data |
|
|
22 |
CML-O |
Rx2p |
Riċevitur Non-Invertited Data Output |
|
|
23 |
GND |
Art |
1 |
|
|
24 |
CML-O |
Rx4n |
Riċevitur Invertit Output tad-Data |
|
|
25 |
CML-O |
Rx4p |
Riċevitur Non-Invertited Data Output |
|
|
26 |
GND |
Art |
1 |
|
|
27 |
LVTTL-O |
ModPrsL |
Modulu Preżenti |
|
|
28 |
LVTTL-O |
IntL |
Tinterrompi |
|
|
29 |
Vcc Tx |
+3.3V Trasmettitur tal-provvista tal-enerġija |
2 |
|
|
30 |
Vcc1 |
+3.3V Provvista tal-enerġija |
2 |
|
|
31 |
LVTTL-I |
LPMode |
Modalità ta 'Enerġija Baxxa |
|
|
32 |
GND |
Art |
1 |
|
|
33 |
CML-I |
Tx3p |
Input tad-Data Mhux Invertita tat-Trasmettitur |
|
|
34 |
CML-I |
Tx3n |
Input tad-Data maqluba tat-Trasmettitur |
Nota 1: GND huwa s-simbolu għas-sinjal u l-provvista (qawwa) komuni għall-modulu QSFP +. Kollha huma komuni fi ħdan il-modulu QSFP + u l-vultaġġi kollha tal-modulu huma referenzjati għal dan il-potenzjal sakemm ma jkunx innutat mod ieħor. Qabbad dawn direttament mal-pjan tal-art komuni tas-sinjal tal-bord ospitanti.
Nota 2: Vcc Rx, Vcc1 u Vcc Tx huma l-provvisti ta' enerġija tar-riċevitur u tat-trasmettitur u għandhom jiġu applikati fl-istess ħin. Ir-rekwiżiti definiti għan-naħa ospitanti tal-Konnettur tal-Kard ta' Xifer Ospitanti huma elenkati fit-Tabella 6. Il-filtrazzjoni tal-provvista tal-enerġija tal-bord ospitanti rakkomandat hija murija fil-Figura 4. Vcc Rx Vcc1 u Vcc Tx jistgħu jkunu konnessi internament fi ħdan il-modulu QSFP+ fi kwalunkwe kombinazzjoni. Il-pinnijiet tal-konnettur huma kull wieħed stmat għal kurrent massimu ta ' 500mA.
7,Dimensjonijiet mekkaniċi

8,Informazzjoni dwar l-ordnijiet
|
Numru tal-Parti |
Deskrizzjoni tal-Prodott |
|
CFTX-DAC100G-CU1M |
QSFP28 Kejbil Passiv ta' Waħħal Dirett (100G QSFP28 - Cu), 1m, AWG:30 , 0ºC ~ +70ºC |
|
CFTX-DAC100G-CU2M |
QSFP28 Kejbil Passiv ta' Waħħal Dirett (100G QSFP28 - Cu), 2m, AWG:30 , 0ºC ~ +70ºC |
|
QSFP28 Kejbil Passiv ta' Waħħal Dirett (100G QSFP28 - Cu), 3m, AWG:30 , 0ºC ~ +70ºC |
|
|
CFTX-DAC100G-CU5M |
QSFP28 Kejbil Passiv ta' Waħħal Dirett (100G QSFP28 - Cu), 5m, AWG:24, 0ºC ~ +70ºC |
Nota: Tista 'tkun dijametru u distanza personalizzati.
It-tags Popolari: glc-lh-sm, Ċina, fabbrika, fornituri, manifatturi, kwotazzjoni, personalizzati, prezz, jixtru